Active Reefer Settings : Public Class
Active Reefer Settings describes the settings required in a Reefer agreed between a Carrier and Shipper when a Booking is made.<br/>Reefer requirements for a Requested Equipment. <br/><font color="#1f1c2b">Condition<u>:</u> Only applicable to active Reefers (Is Non-Operating Reefer set to FALSE)</font><br/>
- Attributes
- Associations From
- Advanced
- Other Links
Attribute |
Scope |
Type |
Temperature Setpoint
|
Private
|
Float
|
Notes:
|
Target value of the temperature for the Reefer based on the cargo requirement.<br/>Target value of the temperature for the Reefer based on the cargo requirement. The temperature is specified in degrees Celsius or Fahrenheit.<br/>
|
|
Temperature Unit
|
Private
|
String(3)
|
Notes:
|
Unit used for the measurement of the temperature expressed in degrees Celsius (CEL) or Fahrenheit (FAH). Condition: required if the temperature setpoint is populated.<br/>
|
|
O2 Setpoint
|
Private
|
Float
|
Notes:
|
The percentage of the controlled atmosphere O2 target value.<br/>
|
|
CO2 Setpoint
|
Private
|
Float
|
Notes:
|
The percentage of the controlled atmosphere CO2 target value.<br/>
|
|
Humidity Setpoint
|
Private
|
Float
|
Notes:
|
The percentage of the controlled atmosphere humidity target value.<br/>
|
|
Air Exchange Setpoint
|
Private
|
Float
|
Notes:
|
Target value for the air exchange rate which is the rate at which outdoor air replaces indoor air within a Reefer container.<br/>
|
|
Air Exchange Unit
|
Private
|
String(3)
|
Notes:
|
The unit of measure for the Air Exchange which can be expressed in either MQH (Cubic Meters per Hour) or FQH (Cubic Foot per Hour).<br/>
|
|
Is Ventilation Open
|
Private
|
Boolean
|
Notes:
|
If true, the ventilation orifice is open. If false, the ventilation orifice is closed.<br/>
|
|
Is Drain Holes Open
|
Private
|
Boolean
|
Notes:
|
Is drain holes open on the container.<br/>
|
|
Is Bulb Mode
|
Private
|
Boolean
|
Notes:
|
Indicator of whether special container settings for handling flower bulbs must be active.<br/>
|
|
Is Cold Treatment Required
|
Private
|
Boolean
|
Notes:
|
Indicator whether cargo requires cold treatment prior to loading at origin or during transit, but prior to arrival at POD.<br/>
|
|
Is Controlled Atmosphere Required
|
Private
|
Boolean
|
Notes:
|
Indicator of whether cargo requires Controlled Atmosphere.<br/>
|
|
Is Precooling Required
|
Private
|
Boolean
|
Notes:
|
Indicator whether reefer container should be pre-cooled to the temperature setting required at time of release from depot.<br/>
|
|
Is Generator Set Required
|
Private
|
Boolean
|
Notes:
|
Indicator whether reefer container should have a generator set attached at time of release from depot.<br/>
|
|
Property |
Value |
isFinalSpecialization: |
0 |