Active Reefer Settings

Header Image
Project:
Active Reefer Settings : Public Class
Created: 10/19/2023 2:43:40 PM
Modified: 12/20/2024 10:57:54 AM
Author: DCSA
Version: 2024.4
Project:
Advanced:
Active Reefer Settings describes the settings required in a Reefer agreed between a Carrier and Shipper when a Booking is made.<br/>Reefer requirements for a Requested Equipment. <br/><font color="#1f1c2b">Condition<u>:</u> Only applicable to active Reefers (Is Non-Operating Reefer set to FALSE)</font><br/>
  • Attributes
  • Associations From
  • Advanced
  • Other Links
Attribute Scope Type
Temperature Setpoint Private Float
Notes: Target value of the temperature for the Reefer based on the cargo requirement.<br/>Target value of the temperature for the Reefer based on the cargo requirement. The temperature is specified in degrees Celsius or Fahrenheit.<br/>
Temperature Unit Private String(3)
Notes: Unit used for the measurement of the temperature expressed in degrees Celsius (CEL) or Fahrenheit (FAH). Condition: required if the temperature setpoint is populated.<br/>
O2 Setpoint Private Float
Notes: The percentage of the controlled atmosphere O2 target value.<br/>
CO2 Setpoint Private Float
Notes: The percentage of the controlled atmosphere CO2 target value.<br/>
Humidity Setpoint Private Float
Notes: The percentage of the controlled atmosphere humidity target value.<br/>
Air Exchange Setpoint Private Float
Notes: Target value for the air exchange rate which is the rate at which outdoor air replaces indoor air within a Reefer container.<br/>
Air Exchange Unit Private String(3)
Notes: The unit of measure for the Air Exchange which can be expressed in either MQH (Cubic Meters per Hour) or FQH (Cubic Foot per Hour).<br/>
Is Ventilation Open Private Boolean
Notes: If true, the ventilation orifice is open. If false, the ventilation orifice is closed.<br/>
Is Drain Holes Open Private Boolean
Notes: Is drain holes open on the container.<br/>
Is Bulb Mode Private Boolean
Notes: Indicator of whether special container settings for handling flower bulbs must be active.<br/>
Is Cold Treatment Required Private Boolean
Notes: Indicator whether cargo requires cold treatment prior to loading at origin or during transit, but prior to arrival at POD.<br/>
Is Controlled Atmosphere Required Private Boolean
Notes: Indicator of whether cargo requires Controlled Atmosphere.<br/>
Is Precooling Required Private Boolean
Notes: Indicator whether reefer container should be pre-cooled to the temperature setting required at time of release from depot.<br/>
Is Generator Set Required Private Boolean
Notes: Indicator whether reefer container should have a generator set attached at time of release from depot.<br/>
Element Source Role Target Role
Equipment Group
Class  
Name:  
 
Name:  
 
Details:
Identifies a possible Active Reefer Setting for this Equipment Group<br/>
Utilized Transport Equipment
Class  
Name:  
 
Name:  
 
Details:
 
Setpoint
Class  
Name:  
 
Name:  
 
Details:
 
Property Value
isFinalSpecialization: 0
Object Type Connection Direction Notes
Gas Flow Rate Unit Enumeration Dependency To  
Temperature Unit Enumeration Dependency To