Active Reefer Settings  : Public   Class
	
	Active Reefer Settings describes the settings required in a Reefer agreed between a Carrier and Shipper when a Booking is made.<br/>Reefer requirements for a Requested Equipment. <br/><font color="#1f1c2b">Condition<u>:</u> Only applicable to active Reefers (Is Non-Operating Reefer set to FALSE)</font><br/>
	
		
			- Attributes
- Associations From
- Advanced
- Other Links
	
		
			| Attribute | Scope | Type | 
						
				| Temperature Setpoint | Private | Float | 
			
				| 
	
		| Notes: | Target value of the temperature for the Reefer based on the cargo requirement.<br/>Target value of the temperature for the Reefer based on the cargo requirement. The temperature is specified in degrees Celsius or Fahrenheit.<br/> |  | 
			
				| Temperature Unit | Private | String(3) | 
			
				| 
	
		| Notes: | Unit used for the measurement of the temperature expressed in degrees Celsius (CEL) or Fahrenheit (FAH). Condition: required if the temperature setpoint is populated.<br/> |  | 
			
				| O2 Setpoint | Private | Float | 
			
				| 
	
		| Notes: | The percentage of the controlled atmosphere O2 target value.<br/> |  | 
			
				| CO2 Setpoint | Private | Float | 
			
				| 
	
		| Notes: | The percentage of the controlled atmosphere CO2 target value.<br/> |  | 
			
				| Humidity Setpoint | Private | Float | 
			
				| 
	
		| Notes: | The percentage of the controlled atmosphere humidity target value.<br/> |  | 
			
				| Air Exchange Setpoint | Private | Float | 
			
				| 
	
		| Notes: | Target value for the air exchange rate which is the rate at which outdoor air replaces indoor air within a Reefer container.<br/> |  | 
			
				| Air Exchange Unit | Private | String(3) | 
			
				| 
	
		| Notes: | The unit of measure for the Air Exchange which can be expressed in either MQH (Cubic Meters per Hour) or FQH (Cubic Foot per Hour).<br/> |  | 
			
				| Is Ventilation Open | Private | Boolean | 
			
				| 
	
		| Notes: | If true, the ventilation orifice is open. If false, the ventilation orifice is closed.<br/> |  | 
			
				| Is Drain Holes Open | Private | Boolean | 
			
				| 
	
		| Notes: | Is drain holes open on the container.<br/> |  | 
			
				| Is Bulb Mode | Private | Boolean | 
			
				| 
	
		| Notes: | Indicator of whether special container settings for handling flower bulbs must be active.<br/> |  | 
			
				| Is Cold Treatment Required | Private | Boolean | 
			
				| 
	
		| Notes: | Indicator whether cargo requires cold treatment prior to loading at origin or during transit, but prior to arrival at POD.<br/> |  | 
			
				| Is Controlled Atmosphere Required | Private | Boolean | 
			
				| 
	
		| Notes: | Indicator of whether cargo requires Controlled Atmosphere.<br/> |  | 
			
				| Is Precooling Required | Private | Boolean | 
			
				| 
	
		| Notes: | Indicator whether reefer container should be pre-cooled to the temperature setting required at time of release from depot.<br/> |  | 
			
				| Is Generator Set Required | Private | Boolean | 
			
				| 
	
		| Notes: | Indicator whether reefer container should have a generator set attached at time of release from depot.<br/> |  | 
	
 
		
		
			
				
					| Property | Value | 
			
				| isFinalSpecialization: | 0 |